Imprimer

Votre recherche pour: Plaques CCM

TLC plates are crucial in analysing mixtures through compound separation to identify the quantity and purity. Product appearances or reactant disappearances are easily observed to show reaction progress. Pre-coated with a thin, uniform layer of solid absorbent, the TLC plates support accurate and reproducible conclusions. Choose from standard sized glass, metal, or plastic constructions compatible with manual or automated testing. Pore sizes may vary among models. Select styles may feature fluorescent indicator for colourless compounds.

TLC plates are crucial in analysing mixtures through compound separation to identify the quantity and purity. Product appearances or reactant disappearances are easily observed to show reaction progress. Pre-coated with a thin, uniform layer of solid absorbent, the TLC plates support accurate and reproducible conclusions. Choose from standard sized glass, metal, or plastic constructions compatible with manual or automated testing. Pore sizes may vary among models. Select styles may feature fluorescent indicator for colourless compounds.


57  résultat(s)

SearchResultCount:"57"

Sort Results

Vue liste Nouvelle Vue

Evaluer les résultats de votre recherche

Fournisseur: Merck
Description: Our NH₂, CN- and DIOL-modified silica sorbents are less polar then conventional silica phases, making them ideal for separating hydrophilic or charged substances. Our moderately polar cyano- and diol-modified silica plates can be used for both normal phase and reversed phase systems. An alternative to PEI cellulose, amino-modified NH₂ plates provide weak basic ion exchange characteristics with special selectivity for charged compounds.
Fournisseur: Merck
Description: Les plaques de silice modifiées CN et DIOL sont modérément polaires et adaptées aux systèmes en phase normale et en phase inversée. La plaque modifiée NH₂ offre des caractéristiques d'échanges d'ions faiblement basiques avec une sélectivité spéciale pour les composés chargés. Elle peut remplacer la cellulose PEI.
Fournisseur: Merck
Description: Le couplage des plaques de CCM et de la spectrométrie de masse est un nouveau domaine de grand intérêt qui contribuera fortement aux progrès effectués en chromatographie planaire. Les plaques de grade MS sont beaucoup plus propres que les plaques de CCM/HPTLC standard et offrent ainsi une plus grande sensibilité et un bruit de fond réduit. Cela permet de réaliser des analyses de traces par spectrométrie de masse dans des ordres de grandeur inférieurs au nanogramme.

Fournisseur: Merck
Description: La gamme de plaques CCM LuxPlate® haute fluorescence contient une quantité accrue d'indicateur de fluorescence, ce qui permet d'identifier aisément les faibles concentration en analytes. En outre, la quantité de liant ajoutée est également plus élevée, ce qui augmente considérablement la luminosité de la plaque CCM, ainsi que la stabilité et la solidité de la surface.
Fournisseur: Merck
Description: Chromatographie en couche mince (CCM/TLC), TLC, MS-grade, Matériau de revêtement: Silice modifiée C18 (RP-18), Matériau: Aluminium, Indicateur fluorescent: F254s, Dimensions de la plaque: 50×75 mm, Épaisseur de couche: 100 µm, Taille de pore: 60 Å

Fournisseur: Avantor
Description: Les feuilles flexibles en polyester pré-imprégnées Baker-flex® possèdent un revêtement dur et résistant à l'abrasion ainsi qu'un substrat résistant aux solvants pour des séparation rapides et propres. On peut découper ces feuilles au format adapté ou bien écrire sur elles.
Fournisseur: VWR Collection
Description: Ces plaques de verre TLC présentent une excellente efficacité de séparation grâce à une distribution optimisée de la taille des particules.

Fournisseur: Merck
Description: Ces plaques CCM d'oxyde d'aluminium utilisent un oxyde d'aluminium neutre ou basique, de porosité de 60 Å ou 150 Å, avec ou sans indicateur fluorescent en fonction des applications.
Fournisseur: Merck
Description: Kieselguhr is a natural diatomaceous earth that can be used for the separation of polar or moderately polar compounds. For the mixed layer plates a combination of classical silica gel 60 and kieselguhr is used, providing favorable properties for certain applications such as separations of inorganic ions, herbicides or steroids.
Fournisseur: Avantor
Description: Chromatographie en couche mince (CCM/TLC), J.T.Baker®, Matériau de revêtement: Gel de silice

Fournisseur: VWR Collection
Description: Ces plaques de verre HPTLC présentent une excellente efficacité de séparation grâce à une distribution optimisée de la taille des particules.

Fournisseur: Merck
Description: HPTLC plates, unmodified silica gel 60
This range of plates uses an optimised Merck silica gel 60 with a particle size of only 5 to 6 µm, which results in higher packing density and a smoother surface, therefore, reducing band diffusion. Less sample is required, 0,1 to 0,5 µl than for classic TLC.

Fournisseur: Merck
Description: Les modifications RP-2, RP-8 et RP-18 utilisent du gel de silice 60 Å modifié avec une chaîne carbonée. La longueur de chaîne, associée au degré de modification, définit la capacité des solvants à tolérer l'eau et influence considérablement la rétention. La durée de migration augmente dans l'ordre suivant: RP-2, RP-8 et RP-18, avec la même composition de solvants. Les phases RP-2 présentent une plus forte polarité et affinité avec les phases aqueuses, tolérant jusqu'à 80% d'eau dans le solvant de migration, alors que les chaînes carbonées RP-8, RP-18 se limitent à 60 et 40% respectivement.
Fournisseur: Merck
Description: Les plaques multiformats de Merck sont des plaques en verre prédécoupées pouvant être fractionnées en différents formats. Elles utilisent la même silice que les plaques CCM ou HPTLC correspondantes, afin de fournir des chromatogrammes identiques à ceux obtenus avec les plaques normales prédécoupées.

Fournisseur: Merck
Description: Les plaques PLC (chromatographie sur couche préparative) sont basées sur la même technologie éprouvée des liants à la silice Merck que les plaques de CCM analytiques. Les plaques sont disponibles avec des couches de gel de silice non modifiées ou de gel de silice modifiées RP-18 en plusieurs épaisseurs de couche de 500 à 2000 µm, avec ou sans indicateur de fluorescence.
Fournisseur: Merck
Description: Les plaques HPTLC LiChrospher® sont basées sur de la silice 60 de forme sphérique avec une taille de particule de 7 µm et une distribution granulométrique étroite similaire aux phases utilisées en HPLC. Les plaques HPTLC LiChrospher® possèdent une sélectivité comparable aux plaques HPTLC respectives, cependant, la hauteur de la plaque et les nombres de séparation sont encore améliorés, ce qui entraîne des temps d'analyse plus courts.
Prix sur demande
Le stock de cet article est limité mais peut être disponible dans un entrepôt proche de vous. Merci de vous assurer que vous êtes connecté sur le site afin que le stock disponible soit affiché. Si l'call est toujours affiché et vous avez besoin d'aide, s'il vous plaît appelez-nous au 01 45 14 89 12.
Le stock de cet article est limité mais peut être disponible dans un entrepôt proche de vous. Merci de vous assurer que vous êtes connecté sur le site afin que le stock disponible soit affiché. Si l'call est toujours affiché et vous avez besoin d'aide, s'il vous plaît appelez-nous au 01 45 14 89 12.
Ces articles ne peuvent pas être ajoutés à votre panier en raison des exigences réglementaires. Veuillez envoyer un e-mail à webshop.fr@vwr.com
Veuillez noter qu'une autorisation peut être nécessaire pour commander ce produit. Un représentant de VWR vous contactera si votre commande le nécessite.
Ce produit a été bloqué par votre entreprise. Veuillez s'il vous plait contacter votre service achats pour plus d'informations.
Le produit original n'est plus disponible. Le remplacement représenté est disponible
Ce produit n'est plus disponible. Des alternatives peuvent être disponibles en faisant une recherche avec la référence VWR ci-dessus. Si vous avez besoin d'aide, s'il vous plaît appelez le Service Clients au 0825 02 30 30 (0,18 € TTC/mn).
1 - 16 of 57
no targeter for Bottom