Imprimer

Votre recherche pour: Membranes de transfert

Highly sensitive transfer membranes use capillary action methods to separate DNA, RNA, or protein fragments for detection. Working well with the gels and buffers required for transfer and immobilization steps, the transfer membranes are durable enough to be subjected to multiple stripping, reprobing, hybridization cycles. The high-binding discs, sheets, and rolls come in various pore sizes and charges to fit any blotting techniques in molecular biology and genetic research.

Highly sensitive transfer membranes use capillary action methods to separate DNA, RNA, or protein fragments for detection. Working well with the gels and buffers required for transfer and immobilization steps, the transfer membranes are durable enough to be subjected to multiple stripping, reprobing, hybridization cycles. The high-binding discs, sheets, and rolls come in various pore sizes and charges to fit any blotting techniques in molecular biology and genetic research.


26  résultat(s)

SearchResultCount:"26"

Sort Results

Vue liste Nouvelle Vue

Evaluer les résultats de votre recherche

Référence Produit: (MILFHATF85R)
Fournisseur: Merck
Description: <p>1 roll, 8,5 cm × 10 m, 0,45 µm pore size, Triton-free, mixed cellulose esters transfer membrane.</p>
UOM: 1 * 1 ROU

New Product


Fournisseur: Cytiva (Formerly Pall Lab)
Description: Les membranes de transfert Biodyne® présentent une sensibilité élevée et un fond minimal pour améliorer la détection et la résolution (idéal pour la détection des acides nucléiques).

New Product

Fournisseur: Merck
Description: Immobilon®-P, Immobilon-P blotting sandwich transfer membranes, 7×8,4 cm

Fournisseur: Merck
Description: <p>Immobilon-NC (HATF) membrane is composed of a mixed cellulose esters matrix. It is devoid of surfactants that may interfere with cell wall integrity during cell growth</p>

Fournisseur: Merck
Description: <p>These Immobilon® PVDF membranes, each optimised for different protein blotting applications.</p>

Fournisseur: Thermo Fisher Scientific
Description: Nitrocellulose membranes are a popular matrix used in protein blotting because of their high protein-binding affinity, compatibility with a variety of detection methods (chemiluminescence, chromogenic, and fluorescence), and the ability to immobilise proteins, glycoproteins, or nucleic acids. Protein immobilisation is thought to occur by hydrophobic interactions, and high salt and low methanol concentrations help improve protein immobilisation to the membrane during electrophoretic transfer, especially for proteins with higher molecular weights. Nitrocellulose membranes are not optimal for electrophoretic transfer of nucleic acids, as the high salt concentrations that are required for efficient binding will effectively elute some or all of the charged nucleic acid fragments.

Référence Produit: (PIER77015)
Fournisseur: Thermo Fisher Scientific
Description: Biodyne™ A nylon membranes are sheets of unmodified nylon that provide excellent binding characteristics for nucleic acid transfer, blotting and detection methods. Biodyne™ A nylon membrane is manufactured with a matrix pore size of 0,45 micron. It contains both negatively and positively charged groups, enabling it to bind many kinds of macromolecules.
UOM: 1 * 25 Pce


Fournisseur: THERMO OWL SCIENTIFIC
Description: Hydrophobic polyvinylidene fluoride transfer membrane has a high signal-to-noise ratio, which allows for the use of mild blocking procedures

Fournisseur: Cytiva (Formerly Pall Lab)
Description: PVDF naturellement hydrophobe, idéal pour un large éventail d'applications d'analyse de protéines. La gamme de milieux FluroTrans® comporte des supports de phase solide microporeux blancs qui lient les protéines avec ténacité par interactions hydrophobes. La membrane FluoroTrans® est optimisée pour le séquençage de protéines N-terminal. La membrane FluoroTrans® W est optimisée pour les applications de transfert Western. La membrane FluoroTrans® W permet une détection sensible des protéines avec un faible signal de fond et une très faible pénétration de protéines. Les protéines immobilisées sont détectées visuellement avec Coomassie® Blue, Amido Black et Ponceau S et de l'or colloïdal.

Fournisseur: Thermo Fisher Scientific
Description: Transfer membranes made of high quality PVDF, which provides high binding capacity for proteins and nucleic acids.

Référence Produit: (PIER77016)
Fournisseur: Thermo Fisher Scientific
Description: Biodyne™ B nylon membranes are sheets of positively charged nylon that provide excellent binding characteristics for nucleic acid transfer, blotting and detection methods. Biodyne™ B nylon membrane is manufactured with a matrix pore size of 0,4 micron. It contains exclusively positive charges, providing the highest possible binding capacity for negatively charged molecules, like DNA and RNA.
UOM: 1 * 25 Pce


Fournisseur: Whatman products (Cytiva)
Description: Protran® membranes are manufactured from 100% pure nitrocellulose to ensure the highest binding capacity possible. They are compatible with a variety of detection methods, including isotopic, chemiluminescent, colorimetric and fluorescent. No methanol pre-wetting step is required, making this the membrane of choice for proteins which prefer aqueous environments. Prior to transfer the membrane is simply wetted with water, and then placed in the transfer buffer. No other pre treatment steps are necessary.

Fournisseur: Whatman products (Cytiva)
Description: Les membranes de nylon Nytran® SuPerCharge (SPC) présentent une charge positive très élevée et une densité de nylon plus élevée par unité de surface. Disponibles en disques, feuilles ou rouleaux pour micro-plaques.

Fournisseur: G-Biosciences
Description: Pre-cut transfer membranes and padding for Western blot transfer procedures. Pre-cut membranes are supplied sandwiched between blotting paper padding. Simply soak the membrane in transfer buffer and assemble with the gel in a transfer cassette. Nitrocellulose (0,22 µm pore size) and PVDF (0,45 µm pore size) membranes are available.

Fournisseur: Whatman products (Cytiva)
Description: La membrane en nylon Nytran® (Nytran® N) est dédiée aux applications nécessitant des charges plus faibles. Elle est conçue pour les procédures Southern et Northern Blotting, ainsi que pour les transferts et répliques de colonies et les méthodes Dot-Blot ou Slot-Blot. Nytran® N est compatible avec les méthodes de détection isotopiques.

Fournisseur: Cytiva
Description: Amersham Hybond™-N+ est une membrane en nylon chargée positivement avec une capacité de liaison des acides nucléiques pouvant atteindre 600 µg/cm², recommandée pour une utilisation avec des systèmes de détection par chimiluminescence et chimifluorescence.

Prix sur demande
Le stock de cet article est limité mais peut être disponible dans un entrepôt proche de vous. Merci de vous assurer que vous êtes connecté sur le site afin que le stock disponible soit affiché. Si l'call est toujours affiché et vous avez besoin d'aide, s'il vous plaît appelez-nous au 01 45 14 89 12.
Le stock de cet article est limité mais peut être disponible dans un entrepôt proche de vous. Merci de vous assurer que vous êtes connecté sur le site afin que le stock disponible soit affiché. Si l'call est toujours affiché et vous avez besoin d'aide, s'il vous plaît appelez-nous au 01 45 14 89 12.
Ces articles ne peuvent pas être ajoutés à votre panier en raison des exigences réglementaires. Veuillez envoyer un e-mail à webshop.fr@vwr.com
Veuillez noter qu'une autorisation peut être nécessaire pour commander ce produit. Un représentant de VWR vous contactera si votre commande le nécessite.
Ce produit a été bloqué par votre entreprise. Veuillez s'il vous plait contacter votre service achats pour plus d'informations.
Le produit original n'est plus disponible. Le remplacement représenté est disponible
Ce produit n'est plus disponible. Des alternatives peuvent être disponibles en faisant une recherche avec la référence VWR ci-dessus. Si vous avez besoin d'aide, s'il vous plaît appelez le Service Clients au 0825 02 30 30 (0,18 € TTC/mn).
1 - 16 of 26
no targeter for Bottom